STRUMENTI

Qui sono elencati gli strumenti di misura più rilevanti a disposizone nel mio laboratorio, che mi permettono di lavorare efficacemente per lo sviluppo dei prodotti dei miei clienti. Ogni tanto la lista aumenta, per cui di tanto in tanto tonate a dare un'occhiata per vedere le novità ;-)

OSCILLOSCOPI

Rigol DS-4024

RIGOL DS-4024

200 MHz bandwidth
4 GSa/s sample rate.
4 channels.
140 million points memory.
110,000 waveforms per second.
Ultravision technology.
Real-time, continuous waveform recording and waveform analysis.
LXI Ethernet remote control.

Bitscope BS326N

BITSCOPE BS326N

100 MHz Analog Bandwidth Digital Scope.
40MS/s Logic Analyzer, 25nS capture.
Dual Analog Channels (4 inputs, BNC & POD).
8 logic/timing channels and Smart Port.
Instant Replay Waveform Generator.
Huge mixed signal capture buffers and logging.
Real-Time Spectrum Analyzer.
Mixed Signal Data Acquisition.
Ethernet Network Connected.
Isolated

Ikascope WS200

IKALOGIC IKASCOPE WS200

Portable wireless digital scope probe.
30Mhz analog bandwidth.
200MS/s acquisition rate.
80Vpp input range.
WiFi connection, full isolation.
Battery recharged via USB.
Android and iOS App for smartphone and tablet.

MULTIMETRI

RIGOL DM3068

RIGOL DM3068

Benchtop RMS digital multimeter (DMM).
6.5 digits of resolution.
5µV noise floor.
DCV, ACV, DCI, ACI, Resistance (2 and 4 wire), Capacitance, Diode Test, Frequency, Temperature.
Datalogging with histogram and trend display.
USB, GPIB, RS232 and Ethernet LXI connectivity and remote control.

Fluke 289

Fluke 289

TrendCapture graphically displays logged data to determine anomalies.
Selectable AC filter (smoothing mode).
Large 50,000 count, 1/4 VGA dot matrix display with white backlight.
Two terminal 50 ohm range with 1 milliohm resolution, 10 mA source current.
Low Pass filter for accurate voltage and frequency measurements
LoZ Volts.
Relative mode to remove test lead resistance from low ohms or capacitance measurements.
True-RMS AC voltage and current for accurate measurements on non-linear signals.
Measure up to 10 A (20 A for 30 seconds).
100 mF capacitance range.

ALIMENTATORI

Rigol DP831A

RIGOL DP831A

3 Outputs, total power 160W.
Low Ripple Noise <350 uVrms/2mVpp.
Fast transient response time: <50 us.
Built in V, A, W measurements and waveform display.
Support for output Delay, Analysis, Monitor, and Preset functions.
LXI Ethernet remote control and Digital IO.

PS-305D

PS-305D

0-30V / 0-5A output.
current-limiting protection.

GENERATORI DI FUNZIONI

Rigol DG-4062

RIGOL DG-4062

60 MHz generators
2 output channels.
500 MSa/s sample rate, 16kpts waveform
130 built-in waveforms.
14 bit vertical resolution.
Arbitrary Waveform Generation, Pulse Generation.
Harmonic Generation, Analog/Digital Modulation.
Frequency Counter
LXI Ethernet remote control.

ANALIZZATORI DI SPETTRO

Atten AT5010

ATTEN AT5010

Frequency range: 0.15~1050MHz.
-100~+13dBm amplitude range, 20MHz, 400MHz center frequency span and 4 KHz video filter.
Sweep rate: 43Hz.
Screen display range: 80dB (10dB/div.).
Sensitivity: Better than -90dBm.
Input attenuator: 0 to 40dB (4×10dB steps)
Max. Input level: +10dBm, ±25V DC (0dB attn.) +20dBm (40dB attn.)
Frequency scans width: 100 kHz/div. to 100MHz/div, in 1-2-5 steps and 0Hz/div. (Zero Scan)

Atten AT5000

ATTEN AT5000-F2

3000MHz frequency expander.
Amplitude range: -27~-100dB.

CONTATORI

Atten F1000-C

ATTEN F1000-C

8-Digit LED display.
Frequency range: 10Hz - 1000MHz.
LED Gate time: 0.01S / 0.1S / 1s.
Accuracy: +/-1Hz +/-1 Count.
Input sensitivity: 10 Hz-10 MHz: 20mV (Channel 1); 10 MHz-100MHz: 25 mV (Channel 1); 100 MHz-1000MHz: 25 mV (Channel 2).
Input impedance: 1Mohms at Channel 1, 50 Ohms at Channel 2
Max input voltage: 250Vrms Channel1; 5Vrms Channel 2.

ANALIZZATORI LOGICI

Ikalogic ScanaPlus

Ikalogic ScanaPLUS

100 MSps, Accuracy: ±10 ns.
Bandwidth: 25MHz.
Sampling lenght: 2000 seconds @ 100Msps (33 minutes).
9 channels.
Logic levels: 1.2V, 1.5V, 1.8V, 2.8V, 3.3V, 5V.
Input voltage: ±35V.
Input impedance: 100K Ω || 5pF.
Integrated RS232 and LIN receivers.
Software-based decoding, fully programmable.
Protocols: UART, SPI, I2C, 1-wire, CAN, LIN 1.x & LIN2.x, Parallel bus, and many more

Ikalogic SP209i

Ikalogic SP209i

9 logic channels with adjustable thresholds (1.8V, 2.5V, 3.3V, 5V)
State of the art input stage, with Schmitt triggers that eliminate glitches on slow signals
200 MHz sampling rate, with all 9 channels used.
External clock option (state mode), up to 50MHz
Precise trigger-In and trigger-Out signals on SMA ports
Samples compression and streaming via USB.
2Gb DDR-3 memory kicks-in when USB isn't fast enough.
Embedded receivers on industrial version: RS232, CAN, LIN, RS485.

ANALIZZATORI VETTORIALI

MiniVNA Tiny

Miniradiosolutions MiniVNA Tiny

USB-based Vector Network Analyzer (VNA).
Frequency range from 1MHz to 3GHz, in steps of 10Hz.
Range of Z from 1 to 1000 ohm.
RF Generator power output of -6dBm @ 500 MHz.
Dynamic range of up to 70 dB @ 500 MHz
Calibration using open-short-load.
Two ports VNA with S11 and S21, SMA connectors.
Full Phase measurement.
Easy to use software for Windows, GNU/Linux and MacOSX.